RXSOL Cooling Pad Cleaner CP is a specialized cleaning formulation developed for the maintenance and cleaning of evaporative cooling pads and associated water distribution components. It helps remove accumulated mineral deposits, scale residues, and stubborn inorganic dirt that can build up during prolonged operation.
The product supports the restoration of clean pad surfaces and helps maintain effective water distribution and airflow through suitable cooling media. Regular cleaning, when performed in accordance with equipment manufacturer recommendations, can help maintain cooling system performance and reduce the accumulation of deposits.
Application
RXSOL Cooling Pad Cleaner CP is intended for evaluating and cleaning suitable components of evaporative cooling systems, including:
- Evaporative cooling pads.
- Industrial air-cooling pad assemblies.
- Cooling media affected by mineral deposits.
- Compatible water distribution channels and associated components.
- Suitable cooling pad surfaces requiring periodic descaling.
Important: Confirm compatibility with the specific cooling pad material and equipment manufacturer's recommendations before use. Do not assume suitability for cellulose, paper-based, impregnated, coated, or polymeric media without compatibility testing.
Dosage & directions
How to effectively CLEAN Cooling Pad Scale Deposits?
- The correct cleaning procedure depends on the cooling pad material, deposit type, deposit thickness, and equipment design.
- Switch off the cooling system and isolate the relevant equipment before cleaning.
- Inspect the cooling pads for mineral deposits, physical deterioration, and material damage.
- Consult the cooling pad manufacturer to confirm chemical compatibility and the approved cleaning method.
- Determine the appropriate dilution, application quantity, and contact time through a controlled preliminary trial.
- Apply the product using compatible equipment and suitable chemical-resistant protective equipment.
- Avoid allowing the product to dry on the surface.
- After the prescribed contact period, thoroughly rinse the cleaned surfaces with clean water using the equipment manufacturer's recommended procedure.
- Ensure that residual cleaner is removed and that the system is suitable for recommissioning before returning it to service.
Product can be directly sprayed on the cooling pad. NOTE: Always test the product on small area before wide scale application.
Handling & precautions
Fast-acting descaler developed to dissolve mineral scale, rust, and water deposits from boilers, heat exchangers, pipelines, and water-cooled equipment. It enhances plant efficiency, lowers maintenance costs, and minimizes downtime — all without requiring heat during cleaning. This non-combustible, non-flammable formula is safe to handle and can even be used while equipment is in operation. Highly effective against calcium carbonate buildup with minimal manpower. Not recommended for aluminum surfaces.
Which is the best Heat Exchanger Copper Tube Descaling Solution?
Notes
• Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders
• Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers
. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.
• Buildings - Chillers, Cooling Towers, Pipework
• Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps
• Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables
• Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps
• Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays
• Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators
• Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps
• Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers
• Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps
• Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers
• Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces
• Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers
Boilers
Condensers
Filters
Heat Exchangers
Kettles & Tanks
Pipelines
Pots
Reactors
Steam Jackets
Bath Rooms and Showers
Metal Processing and much more!
Applications
|
Automotive |
Bottling |
Chemicals |
Food |
|
- Closed Circuit Cooling - Dynamometers - Extruders - Molders - Radiators - Welders |
- CO2 Generators - Heaters - Exchangers - Rinse Tanks - Sterilizers and Washers |
- Dryers - Extruders - Kettles - Mixers - Reactors - Scrubbers - Vacuum Pumps |
- Condensers - Ice Machines - Kathabars - Refrigeration Equipment - Steam Tables |
|
Manufacturing |
Metals |
Mining |
Paper |
|
- Chillers - Compressors - Furnaces - Quenchers - Vacuum Pumps |
- Bearings - Conveyors - Fans - Hearth & Vacuum Furnaces - Shelters - Sprays |
- Bearings - Conveyors - Filters - Presses - Process Lines - Radiators |
- Calendar Rolls - Mill Rolls - Caustic Lines - Scrubbers - Compressors - Liquor Tanks - Pulverizers - Vacuum Pumps |
|
Pharmaceutical |
Refinery |
Rubber & Plastics |
Steel |
|
- Exchangers - Loop Systems - Kathabars - Pumps - Reactors - Stills - Sterilizers |
- Compressors - Converters - Crackers - Exchangers - Piping - Pumps |
- Banbury Mixers - Calendar & Mill Rolls - Extruders - Injection Molders - Molds - Temperature Control - Units - Throat Coolers - Towers and Tubers |
Bearings ConCast Units Generators Hearths Spangle Units Furnaces |
|
Textile |
Utilities |
Other Applications |
|
|
- Air Washers - Compressors - Condensers - Exchangers - Extruders and Towers |
- Boilers - Turbines - Transformers - Cooling Towers - Air Compressors - Hydrogen Coolers - Lube Oil Heat Exchangers |
- Ball Mills - Demisters - Evaporators - Locomotives - Absorption Units - Diesel Generators - Induction Furnaces |
Material safety data (MSDS)

| Product Name | Cooling Pad Cleaner CP |
| Product Code | RXSOL-43-1048-025 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Gandhidham, Chennai, Visakhapatnam, Kolkata, Fujairah, Muscat
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail @ rxmarine.com |

Proprietory blend of cleaning agents.

Odour: Unpleasant odour
Appearance: Liquid, viscous, colourless, soluble in water
Contact with eyes: Corrosive to eyes
Contact with skin: Causes burns (R34), Toxic by inhalation, in contact with skin and if swallowed (R23/24/25)
Ingestion: Can cause damage to the stomach lining

| Contact with skin |
- Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water Rinse skin with plenty of water and if possible with a calcium gluconate gel 10%. Transport immediately to hospital |
|
Contact with eyes |
- If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes , act fast, rinse immediately with plenty of water and seek medical attention. - Irrigate eyes thoroughly whilst lifting eyelids - Seek immediate medical attention |
| Ingestion |
- Do not induce vomiting - Give plenty of water to drink - Use appropriate antacid - Never give anything by mouth to an unconscious person - Seek immediate medical attention |
| Inhalation |
- Inhalation is unlikely to occur - Remove patient to fresh air - Never give anything by mouth to an unconscious person - Give plenty of water to drink - Obtain immediate medical attention |
| General | - In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) |
Always ask medical advice as soon as possible should serious or continuous disturbances occur
Skin contact : remove contaminated clothing,
Eye contact : rinse first with plenty of water and seek medical attention
Ingestion : have mouth rinsed and take to hospital immediately
Inhalation : in case of serious or continous discomforts: remove to fresh air and seek medical attention

- Non combustible passivating paste is a strong oxidizing agent. Strong oxidizer foam CO2, dry powder, fog spray to cool control the fire involve. Do not use water jets
- Smoke from fires is corrosive, Nitrogen oxides may be formed
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
- Smoke from fires is corrosive. Take precautions to protect personnel from exposure

| Personal Precautions |
- Wear protective clothing as per section 8, Self-contained breathing apparatus, safety gloves and shoes/boots should be worn whenhandling containers |
| Environmental Precautions |
- No special precautions are required for this product - Do not flush spilt material into any public water system |
| Immediate Actions |
- Shut off source of leak if safe to do so - Use appropriate containment to avoid environmental contamination (S57) |
| Clean Up Actions |
- Absorb spillage in inert material and shovel up - Ventilate the area and wash spill site after material pick-up is complete |
|
Special Precautions |
- Wear protective clothing as per section 8 - Do not use metal containers for spilled liquid |

| Handling |
- Wear protective clothing as per section 8 - Avoid contact with skin and eyes (S24/25) - Eyewash bottles should be available Acid-corrosive. Exercise care in the choice with metals and reactive substances. Store only in original containers. Ensure good housekeeping. STORE AWAY FROM ORGANIC PIGMENTS AND CHEMICALS |
| Storage |
- Keep only in the original container in a cool, well ventilated place (S3/9/49) - Opened containers should be carefully resealed and stored in an upright position - Recommended storage temperature between 5 and 40 °C |
Shelf life: One year in unopened bottle correctly stored

| Exposure Limits |
- TLV (TWA) 5 mg/m3 (Nitric acid) - STEL 2.5 mg/m3 (Hydrogen fluoride) |
|
Exposure controls |
- The undiluted product must not be used in a confined space without good ventilation |
| Occupational exposure controls |
- Where an air-purifying respirator is suitable, use EN141 or EN405, type B - Wear face mask giving complete face protection - Wear suitable clothing providing resistance to acids - Wear plastic or rubber gloves |
Visor Gloves Suit Respirator

- Odour: Unpleasant pungent odour
- Appearance: Liquid, viscous, colourless, soluble in water
- pH 1 at 1 % concentration
- Boiling point - not known
- Vapour pressure 0.01 kPa at 20 deg C
- Vapour density - not known
- Freezing point 0 °C at 760 mm/Hg
- Completely soluble in water
- Specific gravity (water=1) 1.2 - 1.3
- Non combustible
- Viscosity ~ 2000 mPa.s at 20 deg C

- No hazardous reactions known if used for its intended purpose
- Avoid overheating, Avoid contact with alkalis (strong bases)
- Contact with alkali metals liberates flammable gas, Incompatible with alkalis (strong bases)
- See Section 5, Decomposition products may include nitrogen oxides
- Contact with nitrite (e.g. Diesel DEWT Guard NB NB, ROCCORRX NB Liquid) liberates toxic gas.

Toxicological information
- LD50 (oral,rat) 680 mg/kg
Inhalation
- Can cause damage to the respiratory system
Contact with skin
- Causes burns (R34)
Contact with eyes
- Causes burns (R34)
Ingestion
- The ingestion of significant quantities may cause damage to digestive system
Carcinogenicity
- No evidence of carcinogenic effects

Ecotoxicity
- May cause acute effects in the aquatic environment
- This product does not contain ingredients which are classified in the EU as dangerous for the environment.
Mobility
- Completely soluble in water
Persistence and Biodegradability
- Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently biodegradable.
Bioaccumulation Potential
- Bioaccumulation of the components in this product is insignificant.
Other Adverse Effects
- No environmental problems are expected when the product is used / handled correctly. In its intended use, the product will not be released into the environment.
- Presents little or no hazard to the aquatic environment

Classification
- EU Waste class: 06.01
- This material and/or its container must be disposed of as hazardous waste
Disposal considerations
- Do not discharge into drains or the environment, dispose to an authorised waste collection point
- Disposal should be in accordance with local, state or national legislation

Not classified as dangerous product.

Risk Phrases
- Toxic by inhalation, in contact with skin and if swallowed (R23/24/25)
- Causes severe burns (R35)
Safety Phrases
- Keep container tightly closed and at a temperature not exceeding 45 °C (S7/47)
- Do not breathe vapour/fumes (S23)
- In case of contact with eyes, rinse immediately with plenty of water and seek medical advice (S26)
- Wear suitable protective clothing, eye/face protection and gloves (S36/37/39)
- Avoid release to the environment. Refer to special instructions/Safety data sheets (S61)

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable
Procedure
How to effectively CLEAN Cooling Pad Scale Deposits?
- The correct cleaning procedure depends on the cooling pad material, deposit type, deposit thickness, and equipment design.
- Switch off the cooling system and isolate the relevant equipment before cleaning.
- Inspect the cooling pads for mineral deposits, physical deterioration, and material damage.
- Consult the cooling pad manufacturer to confirm chemical compatibility and the approved cleaning method.
- Determine the appropriate dilution, application quantity, and contact time through a controlled preliminary trial.
- Apply the product using compatible equipment and suitable chemical-resistant protective equipment.
- Avoid allowing the product to dry on the surface.
- After the prescribed contact period, thoroughly rinse the cleaned surfaces with clean water using the equipment manufacturer's recommended procedure.
- Ensure that residual cleaner is removed and that the system is suitable for recommissioning before returning it to service.
Product can be directly sprayed on the cooling pad. NOTE: Always test the product on small area before wide scale application.
Other names
Cooling Pad Cleaner, Cooling Pad Scale Cleaner for Greenhouse
Keywords
- Helps remove mineral scale and inorganic deposits.
- Assists in cleaning heavily soiled cooling pad surfaces.
- Helps improve water distribution through cleaned media.
- Supports maintenance of airflow passages in cooling pads.
- Suitable for controlled maintenance and descaling applications.
- Viscous consistency facilitates controlled application to suitable surfaces.
- Helps maintain the cleanliness of cooling system components.
Packing & supply
Available pack sizes
This descaler was specifically formulated and developed to rapidly clean mineral scales from passages in water-cooled or heated equipment. Safe Acid Descalex Liquid is available in 25, 50 Ltr packs
Supply locations
Cooling Pad Descaling Liquid Manufacturer and supplier in Visakhapatnam Vizag Andhrapradesh, Chennai Ennore Tamilnadu, Kolkata Haldia West Bengal, Gandhidham Surat Gujrat, Mumbai Pune Maharastra, Fujairah UAE Middle East, Dubai, Ajman, Abudhabi, Sharjah, Doha Qatar, Sudan, Kuwait, Muscat Barka Sohar Oman, Yemen, Nairobi Kenya Africa
Need Cooling Pad Cleaner CP for your operation?
Our team helps with product selection, dosage, safety data and delivery worldwide.
Request a quote