SwellPolymer LCM
Part No. RXSOL-81-4160-025
Swelling Polymer Plug LCM Powder
Water soluble polymer for use as Loss Circulation Material in drilling work
Key details
| Part number | RXSOL-81-4160-025 |
|---|---|
| Generic name | Swelling Polymer Plug LCM Powder |
| Supply locations | Swelling Polymer RXSOL LCM is a powder form polyelectrolyte Exporter, Manufacturer, Supplier in Mumbai, Kandla, Kolkata, Visakhapatnam, Chennai, Gandhidham, Fujairah, Sharjah, Ajman, Abudhbai, Dubai, Sohar Barka Muscat Oman, Nairobi, Africa, Canada |
| Usage unit | Kg |
| Quantity per unit | 25.00 |
Need this product at your port or plant?
Enquire NowRXSOL SwellPolymer LCM is a cross-linked, water-swellable polyacrylamide-based polymer designed for use as a Loss Circulation Material (LCM) in horizontal drilling, HDD and drilling-fluid applications.
The dry polymer rapidly absorbs water and expands to many times its original volume, producing a soft, cohesive and highly swollen polymer mass. When placed into permeable zones, fractures, voids or unconsolidated formations, the swollen material helps bridge, seal and reduce fluid losses.
Unlike conventional water-soluble polyacrylamides, RXSOL SwellPolymer LCM is cross-linked and insoluble in water. It retains its polymeric structure while absorbing and holding large quantities of water.
RXSOL SwellPolymer LCM is primarily designed for:
- Horizontal directional drilling (HDD)
- Horizontal drilling operations
- Drilling-fluid loss control
- Fracture sealing
- Highly permeable formations
- Unconsolidated formations
- Gravel and void zones
- Caving zones
- Lost-circulation zones
- Annular loss control
- Borehole stabilization
- Temporary plugging applications
How to use and control Lost Control Material
- Determine the severity and approximate size of the loss zone.
- Select an appropriate particle-size grade.
- Add the required quantity slowly into the circulating drilling fluid.
- Maintain sufficient agitation to achieve uniform dispersion.
- Circulate toward the loss zone.
- Allow sufficient residence/contact time for hydration and swelling.
- Monitor returns and fluid-loss reduction.
- Repeat treatment if required.
- Fill a clean mixing tank with compatible water.
- Start moderate agitation.
- Slowly add RXSOL SwellPolymer LCM.
- Allow the polymer to hydrate and swell.
- Continue mixing until a uniform swollen polymer slurry/gel is obtained.
- Pump or place the swollen material into the designated loss zone.
- Allow sufficient static contact time for formation of the sealing plug.
| Form | Solid |
| Colour | White |
| Odour | None |
| Odor Threshold | Not Applicable |
| pH | 6-8 |
| Melting Point | Not Applicable |
| Flash Point | >100°C |
| Autoignition temperature | >200°C |
| Vapour pressure (mm Hg) | 0.13 @ 20°C |
How does LCM Lost Circulation Material work in drilling?
When the dry polymer comes into contact with water, the cross-linked polymer network rapidly absorbs water.
The polymer particles expand and form a swollen, cohesive mass.
Dry polymer → Water absorption → Rapid swelling → Particle expansion → Fracture/void filling → Loss reduction
The cross-linked structure prevents the polymer from simply dissolving into the drilling fluid. Instead, the material maintains its three-dimensional polymer network while retaining absorbed water.
Key Features of using RXSOL LCM Swelling Polymer
- Rapid water absorption and swelling
- Can be pre-hydrated before application
- Swells several hundred times its dry volume under suitable conditions
- Helps seal fractures, voids and permeable formations
- Effective in unconsolidated and caving formations
- Useful for horizontal drilling and HDD operations
- Non-fermenting polymeric material
- Easy to handle, mix and apply
- Economical compared with many conventional LCM systems
- Remains as a cohesive swollen mass after hydration
- Particle size can be selected according to loss-zone characteristics

| Product Name | SwellPolymer LCM |
| Part Number | RXSOL-81-4160-025 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Hazira Surat, Mumbai, Chennai,Vizag, Kolkata, UAE, Oman, Nairobi KENYA
| Phone | +91 22 2087 1200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| 123 @ rxmarine.com | |
| Website | www.rxmarine.com |

Proprietory blend of non-hazardous polyelectrolytes.

| Signal Word | Not Applicable . Not Classified |
| Hazard Statements |
This chemical is not considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) Not a dangerous substance or mixture according to the Globally Harmonized System (GHS) |
| Hazards not classified (HNOC) | Not Applicable |
| Other hazards |
Not available |

| Eye Contact |
Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention. |
| Skin Contact | In case of contact, immediately flushes skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Cover the irritated skin with an emollient. Cold water may be used.Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention. |
| Inhalation: | Move to fresh air. If breathing is difficult, give oxygen. Get medical attention immediately if symptoms occur. |
| Ingestion: | Do not induce vomiting. Obtain medical attention.If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. |
| Notes to Physician | Treat symptomatically |

| Flammability | Not Flammable |
| Flash Point | Not Applicable |
| Suitable extinguishing media | Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |
| Hazardous combustion products | No data available |
| Protective Equipment | Use personal protective equipment. |
| Specific Hazards Arising from the Chemical | No Information Available |

| Spillage | Stop leak if you can do it without risk. Cover with plastic sheet to prevent spreading.Sweep up and shovel into suitable containers for disposal. Clean contaminatedsurface thoroughly. |
| Personal Protection | Ensure adequate ventilation. Use personal protective equipment. Avoid contact withskin, eyes and clothing. Avoid dust formation. Remove all sources of ignition. |
| Enviromental Precaution | Prevent further leakage or spillage. Prevent product fromentering drains. |
|
Methods for containment and cleaning |
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions. Take up dry. Dispose of properly. Clean up the affected area. Avoid generation of dust |

| Handling |
Provide sufficient air exchange and/or exhaust in work rooms. Avoid dust formation. All equipment usedwhenhandling the product must be grounded. Keep away from incompatible materials.Wear personal protective equipment. Avoid contact with skin, eyes and clothing. Keep away fromheat andsources of ignition. Do not ingest. Do not breathe dust. Handle in accordance with good industrial hygieneandsafety practice. |
| Storage | Keep container tightly closed in a dry and well-ventilated place. Store at room temperature in the original container |

| Engineering Control | Ensure adequate ventilation. Use process enclosures, local exhaust ventilation, or other engineeringcontrolstokeep airborne levels below recommended exposurelimits.If user operations generate dust, fume or mist, useventilation to keep exposure to airborne contaminantsbelow the exposure limit. | ||||||||||||||||||||||||
| Personal Protection |
Eye protection: Safety glasses with side-shields or Goggles Skin and body protection: Long sleeved clothing. Chemical resistant apron. Gloves. Respiratory protection: Effective dust mask. Hygiene measures: Avoid contact with skin, eyes and clothing. Wash hands before breaksandimmediately after handling the product. When using, do not eat, drink or smoke. |
||||||||||||||||||||||||
| Exposure Limit |
United State
Canada
|

| Form | Solid |
| Colour | White |
| Odour | None |
| Odor Threshold | Not Applicable |
| pH | 6-8 |
| Melting Point | Not Applicable |
| Flash Point | >100°C |
| Autoignition temperature | >200°C |
| Vapour pressure (mm Hg) | 0.13 @ 20°C |
| Flammability (solid, gas) | No Data Available |
| Explosive limits | No Data Available |
| Vapour pressure | No Data Available |
| Vapour Density | No Data Available |
| Bulk Density | No Data Available |
| Partition coefficient | No data available |
| Explosive properties | None |
| Solubility | Soluble in water |

| Stability | Product is stable, no hazardous polymerization occur. |
| Materials to avoid | Oxidizing agents may cause exothermic reactions. |
| Hazardous decomposition products | No decomposition if stored and applied as direct. Burning of the dried material can produce: hydrogen chloride gas, chloride gas, nitrogen oxides (Nox) & carbon oxides |

| Rout Of Entry | Inhalation. Ingestion. |
| Acute Toxicity Oral | LD50/oral/rat>5000 mg/kg |
| Acute Toxicity Dermal | The product is not considered toxic based on studies on laboratory animals. |
| Inhalation |
The product is not expected to be toxic by inhalation |
| Skin | May cause skin irritation with susceptible persons |
| Eye | Testing conducted on rabbits showed minor transient irritation which cleared within days |
| Sensitization | The product is not expected to be sensitizing |

| Eco Toxicity | The aquatic toxicity is high mitigated by the presence of dissolved organic carbon in the water. Results obtained using the US EPA “ Dirty Water “ test show that irreversible adsorption onto suspended matter and dissolved organics (such as humic and other organic acids) present in natural waters, reduces the toxicity to aquatic organisms by a factor of over 10. |
| Environmental fate | The product is rapidly eliminated from the aquatic medium through irreversible adsorption onto suspended matter and dissolved organics. |
| Products Biodegradation: | No Information available |
| Mobility in soil | No Information available |
| Other adverse effects | No Information available |

| Waste treatment Method | Waste material must be disposed of in accordance with the national and local regulations. |
|
Contaminated packaging |
Rinse empty containers with water and use the rinse water to prepare working solution. Can be landfilled or incinerated, in compliance with local regulations. |

| UN Number | Not Regulated. This product is not hazardous in any mode of transport. |
| Proper shipping name | The product is not covered by international regulation on the transport of dangerous goods |
| Transport hazard class(es) | |
| ADR/RID | Hazard class/division Not regulated |
| Subsidiary risk IMDG | Hazard class/division Not regulated |
| Subsidiary risk IATA | Hazard class/division Not regulated |
| Packing group | |
| Packing group | Not regulated |
| Environmental hazards | |
| Environmental hazards | No |
| Marine pollutant | No |
| ADR/RID | |
| Hazchem code | ADG 3Z |
| Tunnel Category | Not Reguted |
| IMDG | |
| EmS Code | Not Reguted |
| IATA | |
| Packing Instruction (Cargo) | Not Reguted |
| Maximum quantity | Not Reguted |
| Packing Instruction (Passenger) | Not Reguted |
| Maximum quantity | Not Reguted |

| Fedral State Regulation | This product is not federally regulated as a hazardous material. |
| Clean Air Act | No information is available. |
| Component Analysis | No information is available |
| DSCL (EEC) | This product is not regulated by any state as hazardous material. |

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if RX Marine International has been advised of the possibility of such damages.
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
|
How to use and control Lost Control Material
- Determine the severity and approximate size of the loss zone.
- Select an appropriate particle-size grade.
- Add the required quantity slowly into the circulating drilling fluid.
- Maintain sufficient agitation to achieve uniform dispersion.
- Circulate toward the loss zone.
- Allow sufficient residence/contact time for hydration and swelling.
- Monitor returns and fluid-loss reduction.
- Repeat treatment if required.
- Fill a clean mixing tank with compatible water.
- Start moderate agitation.
- Slowly add RXSOL SwellPolymer LCM.
- Allow the polymer to hydrate and swell.
- Continue mixing until a uniform swollen polymer slurry/gel is obtained.
- Pump or place the swollen material into the designated loss zone.
- Allow sufficient static contact time for formation of the sealing plug.
Swelling Polymer LCM Plug manufacturer and supplier in Middle East : UAE, Oman Saudi Arabia.
SwelPoly LCM, Lost Circulation Material, Lost Circulation Polymer
How to control lost circulation?
Depending on the particle size and concentration used, RXSOL SwellPolymer LCM can work through several mechanisms:
Particle Bridging
Polymer particles enter openings and bridge across fractures and permeable pathways.
Swelling
Following water contact, particles expand and occupy additional pore/fracture volume.
Plug Formation
Swollen particles consolidate into a flexible plug that restricts further drilling-fluid movement.
Formation Stabilization
The swollen polymer can help bind loose or unconsolidated material and reduce fluid invasion.
Need SwellPolymer LCM for your operation?
Our team helps with product selection, dosage, safety data and delivery worldwide.
Request a Quote