RO CLEANER 4030

RO Chemicals-33

RO CLEANER 4030

Part No. RXSOL-33-3345-260

RO CLEANER 4030 is a low pH liquid cleaner designed to remove metal foulants such as iron, manganese, and aluminium as well as calcium carbonate scale deposits from spiral wound polyamide and cellulose acetate elements. RO CLEANER 4030 is made according to ANSI/NSF Standard 60 for use as an off-line

Key details

Part number RXSOL-33-3345-260
Available pack sizes 30 Kg, 260 Kg and 1350 Kg IBC
Supply locations RO CLEANER 4030 Manufacturer and supplier in Mumbai, Dubai, Muscat, Nairobi, Kenya, Gandhidham, Surat, Chennai, Visakhapatnam, Sharjah, Ajman, Abudhabi, UAE, Ruwi Barka, Sohar, Kolkata, Paradip, Sudan, Yemen
Usage unit Kg
Quantity per unit 260

Need this product at your port or plant?

Enquire Now

RO CLEANER 4030 is a low pH liquid cleaner designed to remove metal foulants such as iron, manganese, and aluminium as well as calcium carbonate scale deposits from spiral wound polyamide and cellulose acetate elements. RO CLEANER 4030 is made according to  ANSI/NSF Standard 60 for use as an off-line cleaner in drinking water systems.

Scale deposits remover from spiral wound polyamide and cellulose acetate elements.

 

Appearance

: Clear, amber liquid

pH (2% solution)

: 2.5 -3.50

Specific Gravity (@25°C)

: 1.35

 

PERFORMANCE :

RO CLEANER 4030 offers an array of performance benefits:

  • Compatible with all polyamide and cellulose acetate membranes.
  • Contains a special blend of buffers, chelants, and reducing agents, to promote the dissolution of metal deposits.
  • Superior results to generic citric and hydrochloric acid solutions.
  • Highly buffered to resist pH changes during the cleaning process.
  • Can be used in conjunction with other applicable cleaners to remove combination foulants.
  • Temperature compensated to maintain optimum pH over a wide temperature range.

Use Instructions:

1. Fill the cleaning tank to the desired volume with RO permeate or DI water. Heat the solution to the maximum acceptable temperature (see membrane manufacturer guidelines) as this will dramatically increase the cleaning efficiency. Add sufficient RO CLEANER 4030  to create a 2% wt/wt solution if the fouling is moderate/severe or 1% if the fouling is mild. Recycle the solution through the cleaning tank to ensure adequate mixing.

2. Recirculate the cleaning solution through each RO system stage, one at a time, for a minimum of 60 minutes at the flow rate recommended by the membrane
manufacturer. If that rate is not known, use the guidelines listed below:

 

Element Diameter, inches

Flow Rate per Vessel, gpm (m3/hr)

4

10 (2.4)

8

40 (9.0)

3. If the membranes are heavily fouled and the recirculated cleaning solution becomes discolored or turbid, discard as much as 15% of the solution volume. Heavily fouled elements may also benefit from a soak period (up to 8 hours).

4. Monitor the pH of the solution during the cleaning process. If the pH remains in the desired range and the solution is not turbid, it may be used to clean subsequent stages. In the unlikely event the pH rises, prepare a new batch and repeat steps 1-4.

5. When the clean is completed, rinse the membranes by recirculating RO permeate through each pressure vessel. To comply with NSF standards, the cleaner should be flushed out with 5 bed/volumes of water before putting the system back on-line.

RoClean L403

Need RO CLEANER 4030 for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote