Hydro Testing Oxy Scavenger Biocide
Hydro-testing corrosion protection for Pipeline, Tank
Hydro Testing Oxy Scavenger Biocide is a multicomponent, multifunctional formulation which prevents corrosion, microbiological growth in single product treatment programme. Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications.
PERFORMANCE:
CORROSION: Effectively prevents corrosion due to Carbon Dioxide, inorganic salts, dissolved oxygen & Hydrogen sulphide contamination from sour fluid or bacterial action. The inhibitor acts as a cathodic polarizer
MICROBIOLOGICAL GROWTH: Effectively prevents the metabolic function necessary for reproduction of the bacteria cell. Successfully prevents anaerobic/aerobic and sulphate reducing bacteria.
Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications
Hydro Testing Oxy Scavenger Biocide can be fed directly or through chemical doses pump. Doses may vary with the quality of water to be treated and the residence time of the water in the system.
Actual consumption is determined under operating conditions.
Benefit / Advantage of using Hydro Testing Oxy Scavenger Biocide:
-
Hydro Testing Oxy Scavenger Biocide is a liquid multifunctional chemical designed to completely treat hydrostatic test fluid, saltwater packer fluid, saltwater drilling fluid, during Hydro-testing and oil field water injection programme.
-
Hydro Testing Oxy Scavenger Biocide contains an effective filming corrosion inhibitor, oxygen scavenger and biocide, altogether in a single formulation convenient to dose with single chemical injection pump or skid.
- Hydro Testing Oxy Scavenger Biocide is economical to use as handling is limited to one chemical.
Form | Liquid |
Colour | Colourless to slightly Yellow |
Odour | Sharp |
Flash Point | > 100C |
Density | 1.05-1.11 g/cm3 (25C) |
pH |
3 - 7 |
Non-Flammable
Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels. Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action. Can be applied for hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.
Pipeline corrosion inhibitor manufacturer and supplier. Hydro Testing Oxygen Scavenger provide complete protection against rust and scale.
Chemical for conditioning of hydro test water i.e. blend of corrosion inhibitor, one Oxygen scavenger, one scale inhibitor & one biocide
The major factor which contributes to the corrosion in hydro-static test water is the dissolved oxygen and dissolved solids do not have much impact on the corrosion rate except the chloride content. The presumptions like not using the corrosion inhibitor if the water is not with high mineral content could beM disastrous as in fact any corrosion process, even a very mild one, will be accompanied by the set up of galvanic cells and formation of corrosion products deposits. Such environment makes the conditions ideal for the corrosion process to continue at accelerated rate once the process fluid will be run through the line.
Hydro Testing Oxy Scavenger Biocide is Hydro-testing oxygen scavenger for Pipeline, Tank. Hydro Testing Oxygen Scavenger Chemical for conditioning of hydro test water i.e. blend of corrosion inhibitor, one Oxygen scavenger, one scale inhibitor & one biocide manufacturer exporter and supplier Mumbai, Surat, Gandhidham, Chennai, Ennore, Visakhapatnam, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Dubai UAE Middle East, Muscat Oman Sohar
Effect of Micro – Organisms:
All water used for Hydro-testing generally contains iron bacteria and sulphate reducing bacteria. The iron bacteria attack to the pipe wall mostly at 6 o’clock location and produces tubercle of iron oxide by metabolic action. Below the tubercles, sulphate reducing bacteria grows and generates H2S from sulphate of water. The H2S goes on reacting with iron forming Fe2S. This is combined with auto catalytic formation of HCI under tubercle and lead to deep pitting and perforation of the pipe wall. The mechanism is more pronounced under stagnant condition and is relevant of Hydrostatic testing.
Risk of serious damage to eyes. In case of contact with eyes, rinse immediately with plenty of water & seek medical advice. Wear suitable gloves and eye / face protection