FREE SHIPPINGFree shipping on all orders over 100000 INR.

Scale Remover 1507

0
No votes yet

Product Qty Per Unit: 
25.00
Product usage unit: 
Ltr.

Negotiate Price

Product Delivery Locations: 
Navi Mumbai, Vashi, Turbha, Rabale, Pawna, Nerul, Taloja, Nashik, Pune, Nagpur, MIDC, Vapi ... More locations >>
Category: 
Boiler Chemicals-42
Generic Name: 
Colour Indicator Scale Remover Powder

Scale dissolver. Specifically formulated to remove rust and water scale build up from boiler evaporators, heat exchangers, cooling systems, pipeline collection system etc. Highly effective on heating. Safe and easy handling and storage.

Product Description: 

Fast and effctive scale remover. It is a superior heavy duty POWDER containing accelerators, corrosion inhibitors & wetting agents with scale dissolver. Specifically formulated to remove rust and water scale build up from boiler evaporators, heat exchangers, cooling systems, pipeline collection system etc. Highly effective on heating. Safe and easy handling and storage.

-   Non-combustible solid
-   Also can be use for removal of loose corrosion products, Organic Foulant, And deposition of clay and SILT deposit.
-   Biodegradable chemical compound without FUMES increases its popularity and also makes it EASY to HANDLE.

Scale and Rust Remover (Powder)

RXSOL-54-1008-025 is a dry acid cleaner formulated to remove rust and scale deposits from  boilers, diesel engine cooling water systems, condensers, evaporators, calorifiers and heat exchangers.

This product is compatible and suitable with aluminum, copper, zinc, galvanized metals, steel boilers etc.

Powder Acid for Removal of Scale and Rust

Product Application: 

APPLICATION : Boilers, calorifiers, heat exchanges, diesel engine cooling system, condensers, evaporators & other type of equipment where rust & scale form. 

Appearance Powder ( with indicator )  
Density         1.2g/cm3
pH                 (10 wt %):1.1
Compatibility
Metal    Suitable aluminium, zinc, tin and their alloys. Stainless steel, Carbon Steel, Cast Iron, Titanium, Copper , Copper alloys, PVC, Plastic , Rubber  Rubber No known effect
Rubber No known effect
Product Procedure: 

Suitable and very popular product for DESCALING of high and low pressure boilers, Heat EXCHANGERS etc. Its corrosion inhibitor blend PROVIDE metal protection

This is mixed with fresh water 3 to 20 percent depending on deposition of scaling. After using SA-1008, sense all metal surfaces with 0.5 percent of RXSOL-54-1008-025 at least 2-4 house , up to neutrial of PH valve.
 

Procedure-of-use: The most effective descaling is accomplished by circulation.In the case of small components,the soak method in an immersion bath can be used. If the equipment to be cleaned is contaminated by oil, grease or sludge, then pre-cleaning with DEGREASER ( RXSOL OB 1005 ) is necessary. Depending on the extent of scaling, use a solution of 2.5-10% RXSOL-54-1008-025 . The solution will have a red colour which changes to orange when 85% of the acid has been neutralized , & to colourless  when the solution is totally neutralized. Whenever possible, the solution should be heated to 60°C.Neutralised  solutions can be re-activated by adding more RXSOL-54-1008-025  until the red colour reappears. This should not be done more than twice. RXSOL-54-1008-025  should not be used on Aluminium , Zinc, Tin or Galvanized surfaces.

Fields: Descaling of  Boilers, Descaling  of Diesel Engine Cooling Systems, Condenser, Pipeline collection system, Evaporators, Calorifiers, Heat Exchangers,The strength of the acid can be enhanced by adding 1part sodium chloride (common salt) to 20 parts of Descalex.If salt is not available, an acceptable alternative is to dissolve RXSOL-54-1008-025  in sea water. After use of RXSOL-54-1008-025  a  0.5% solution of Alkalinity Control in fresh  water should be used for neutralization.

Evaporators, Calorifiers, Heat Exchangers:
The strength of the acid can be enhanced by adding 1 part sodium chloride (common salt) to 20 parts of Descalex. This enhancement of the cleaning solution, however, should not be used when descaling diesel engine cooling water systems. After use of Descalex a 0.5% solution of Alkalinity Control in fresh water should be used for neutralisation.

Product Note: 

HS CODE 34021300

Characteristic:
-Powder product-safe and easy handling and storage.   
-Fast and effective scale remover,It is water-soluble,non-flammable, non-volatile and non-hydroscopic Inhibitors
-protect metals. Requires no heating unless its activity is required to increase fast.Contains anti-foam agent . 
-Colour indicator shows solution strength.
-Removes scale from boilers.                                                                                                 
-Removes scale from Diesel Engine cooling systems.                                                                                   
-Removes scale and rust from Condensers, Evaporators,Heat Exchangers etc.



OTHER VALUABLE PRODUCT :::

Descaling Liquid ::: Part No - RXSOL-11-1008-020 - Scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boiler rupture , To increas usable life of cleaned equipment , it is safe and effective way to remove scale deposits. Click Link - www.rxmarine.com/descaling-liquid-20-ltr

 


Safe Acid Descalex powder ::: Part No - RXSOL-54-1008-025 - superior , heavy duty, POWDER acid containing accelerators, corrosion inhibitors & wetting agents . Specifically formulated to remove rust and water scale build up from boiler evaporators, heat exchangers, cooling systems, pipeline collection system etc. Click Link - www.rxmarine.com/safe-acid-pwd-descalex-powder

SCALE GUN RX ::: Part No - RXSOL-11-1097-025 -  Descaler for Washing Machine. Click Link - www.rxmarine.com/SCALEGUN
 

Lime Scale Remover ::: Part No - RXSOL-11-1052-025 -  lime eater dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. Click Link - rxmarine.com/lime-remover

Descalex Powder ::: Part No - RXSOL-15-1009-025 - Descalex is a dry acid cleaner formulated to remove rust and scale deposits. Click Link -  rxmarine.com/descalex-powder

Scale Remover Hard water ::: Part No - RXSOL-11-1102-025 - This is powerfull concentrated and newly developed cleaner , which contain amphoteric penetrants for dissolving hard water scale. Click Link -  www.rxmarine.com/SCALEREMOVERHardwater

Scale Mineral Cleaner ::: Part No - RXSOL-15-3011-025 - Safe Acid Mineral Cleaner Very effective products to remove MINERAL SCALE deposits from SURFACES Click Link - www.rxmarine.com/mineral-cleaner
 

RXSOL Zyme Descaler 25 Ltr ::: Part No - RXSOL-11-1053-025 - The environmentally friendly and efficient treatment for urine scale build-up in vacuum pipes.This Product prevents scale and keeps sewage flowing freely. Routine use of Product puts an end to scale altogether. Click Link -  www.rxmarine.com/Zyme-Descaler
 

Hydrocarbon Scale Deposit Remover ::: Part No - RXSOL-11-1672-025 -  Solid Hydrocarbon deposition on heat exchanger tube is bigest problem in industrial line. RXSOL-11-1672-025 helps removal of such deposition in an efficient and environmentally friendly manner. Its unique formulation  dissolves hydrocarbon deposits and removed from the heat exchanger tube bundle quickly. . Click Link - http://www.rxmarine.com/Hydrocarbon-Scale-Deposit-Remover

Scale Inhibitor ::: Part No - RXSOL-16-1056-025 - Treatment is used to reduce the concentration of scale forming compounds that can accumulate in production wells, water and disposal wells, flowlines and surface equipment. Click Link -  www.rxmarine.com/water-Scale-Inhibitor

 


Descalex Polymer ( Heat Exchanger) ::: Part No - RXSOL-40-1048-025 -  safe and effective way to remove scale deposits from all types of water-cooled and water-heated equipment..  Click Link -  www.rxmarine.com/safe-acid-descalex-liquid-20-ltr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Technical Specification: 

PRODUCT PROPERTIES of Safe Acid Descalex powder

HS CODE of Safe Acid Descalex powder 34021300

Appearance Reddish / Yellowish / white – Powder ( without indicator )  
Density 1.2g/cm3  
pH (10 wt %):1.1  
Compatibility  
Metal    Avoid aluminium, zinc, tin and their alloys. Avoid galvanised surfaces  
Rubber No known effect  
Packaging Order No.: RXSOL-54-1008-025 Size (in kg)25 , 5
Product pack size: 
5 / 10 / 20 / 25 / 50 Kg jar
Product alias: 
<p> INDION 1507 Colour Indicator Scale Remover Powder</p>

The scale remover contains colour pH indicator with scale dissolving Dry Acid powder which is effectively  dissolves Scale and presence of  corrosion inhibitor protect metal steel parts, cast iron and copper alloys during descaling process And  wetting agent component of scale remover enhance cleaning action which is resulting quick descaling cleaning operation.

Scale remover manufacturer and supplier in Karwar, Visakhapatnam, chennai, Ennore, Kolkata, Haldia, Mumbai, Kandla, Surat, Fujairah, Sharjah, Dubai, Abudhabi, UAE Muscat Oman

1507 Colour Indicator Scale Remover Powder is very effective scale dissolver.

Articles: 
Remarks: 

-   Prevent run off water from entering drains if possible

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT